Session “Circular Kernel Context Logger” Stopped Due To The Following Error: 0xc0000188

Has your monitor or computer’s screen stopped working properly? Is there an error code 0xc0000188 in the Event Viewer? You’ll discover an easy fix for this problem in this article.

Since Windows 7, some users have noticed a strange display behaviour that can be extremely frustrating. Even if you can hear the sounds of your computer’s operating system, the display turns black or grey and it becomes unusable since you can’t see anything.

Session "Circular Kernel Context Logger" Stopped Due To The Following Error: 0xc0000188

The Event Viewer can be used by some people to see whether there are any recent issues. The following message was one of the mistakes:

Read Also:

  1. It Looks Like You Don’t Have Permission To Save Changes To This File
  2. Raw-Mode Is Unavailable Courtesy Of Hyper-V. (Verr_Supdrv_No_ Raw_Mode_Hyper_V_Root).
  3. Anyconnect Was Not Able To Establish A Connection To The Specified Secure Gateway

When it comes to system monitoring and troubleshooting in Windows, the Circular Kernel Context Logger is a term you may stumble upon. While the name may sound complex, understanding its role, associated errors like 0xc0000188, and other file size-related aspects can provide valuable insights into Windows operations.

In this detailed guide, we’ll dive into what Circular Kernel Context Logger is, explore the causes of its stopping errors, and discuss maximum file sizes and filesystem limitations.

What is Circular Kernel Context Logger?

Circular Kernel Context Logger is an Event Tracing for Windows (ETW) component that records system events in a circular buffer. Essentially, this logger helps in system diagnosis by capturing real-time data regarding the operations of kernel components.

It stores this data in a .etl file, which can be accessed and analyzed for troubleshooting system-related issues.

Causes of Session “Circular Kernel Context Logger” Stopped Due To The Following Error: 0xc0000188

One of the common errors associated with the Circular Kernel Context Logger is the 0xc0000188 error. This error typically occurs when the logger is unable to write data to the log file due to size limitations.

Here are some probable causes:

  • Full Disk Space: When your system runs out of disk space, the logger can’t continue recording.
  • File Size Limit Reached: If the maximum file size of the session is reached, the logger will stop.
  • Corrupt Files: Sometimes, corrupted system files can cause this error.
  • Software Conflicts: Occasionally, other software or applications running in the background can conflict with the logger, leading to this error.

Activate SuperFetch.

You may notice the message “session ‘circular kernel context logger’ halted due to the following error 0xc0000188” if you have disabled the Superfetch service.

Whether you’re unsure whether or not the Superfetch service is active, you can activate it and then check to see if it is:

  1. In order to begin, you must first open the Run window. Alternatively, you can type “run” into the Start Menu search bar or press Win + R.
  2. Select Run and type the command services.msc and press Enter.
  3. Double-click on the Superfetch service in the Services pane once you’ve arrived there.
  4. Select Automatic from the Startup type dropdown menu in the Properties window.
  5. Close the Services window by using the Apply and OK buttons.
  6. Restart your computer and check to see whether the error is gone from your computer’s display.

Increasing the File Size of Startup Event Trace Sessions

It’s possible that your operating system is showing a grey screen because your Startup Event Trace Sessions are too small.

Because it’s a bug, this problem should be resolved by applying the most recent updates. However, if you don’t want to do that, you can try to manually adjust the maximum file size as follows:

  1. Run dialogue must be reopened with the keyboard shortcut The combination of Win and R
  2. To open the Performance Monitor window, copy the command perfmon and click on OK.
  3. To the left of the screen are a number of possible routes you can choose. As a result, take the following route: The Startup Event Trace Session Data Collector Sets
  4. Once you’ve found the ReadyBoot line, you’ll need to scroll down on the right side. Open the Properties window by double-clicking on it.
  5. Go to the Stop Condition tab and set the maximum file size to 40MB. You can either utilise the arrows or enter the number manually to accomplish this task.

I sincerely hope that this short guide will assist you in resolving this issue and restoring normal operation to your computer. If you still need assistance, feel free to post a comment in the space below.

Regardless, if you wish to restore the functionality of your computer, I recommend that you utilise a restore point. The System Restore tool can be located by performing a Start Menu search for the word “restore.”

What is the Maximum File Size for Session Circular Kernel Context Logger?

The default maximum file size for the Circular Kernel Context Logger is set to 100 MB in most Windows systems. Once the .etl file reaches this limit, older data gets overwritten by new events, allowing the file to maintain a ‘circular’ logging system.

However, it’s worth noting that the size can be manually adjusted through Windows Registry or Performance Monitor, although it’s generally not recommended unless you are certain about what you are doing.

What is Filesystem Size Limit?

The filesystem size limit refers to the maximum file size or disk size that a particular filesystem can handle. For example:

  • FAT32: Supports individual files up to 4 GB and volumes up to 8 TB.
  • NTFS: Can handle files as large as 18.4 million TB and similarly large volumes.
  • exFAT: Designed for flash drives, it can support files and volumes much larger than FAT32 but smaller than NTFS.

Understanding the filesystem you are using is crucial, especially when dealing with large files or requiring extensive disk space.

Read Also:

  1. There Are Some Data After The End Of The Payload Data
  2. Your Organization Has Disabled The Ability To Change Some Options
  3. Please Insert The Last Disk Of The Multi-Volume Set And Click Ok To Continue

In conclusion, the Circular Kernel Context Logger plays a vital role in system monitoring and troubleshooting within the Windows environment. While it usually operates seamlessly, errors like 0xc0000188 can occur due to various reasons such as disk space limitations or file size restrictions.

Knowing the maximum file size it can handle, as well as the limitations of your filesystem, can help you prevent or resolve issues effectively.